Pengaruh Total Harmonic Distortion Terhadap Power Factor Pelanggan Rumah Tangga 900 – 2200 VA Dusun Tujuh Bubung Kepulauan Bangka Belitung

Ummi Khofifah Qodariah Ramadhani, Asmar Asmar, Wahri Sunanda

Submitted : 2022-07-01, Published : 2022-08-02.

Abstract

The high content of harmonics in an electric power system can cause several disturbances to the system, such as increasing power losses in the system, causing various damage to electrical equipment, and causing the use of electrical energy to be ineffective. Harmonics is caused by the operation of non-linear electrical loads. The interacting harmonic currents with the supply system impedance distorts the supplier's output current and voltage which in turn adversely affects the loads connected to the system and the supply itself. This study aims to analyze the quality of THD in Bubung Tujuh Hamlet, Sangku Village. In this study, THD measurements were carried out and analyzed the effect of harmonics on the power factor using a linear regression test. The results of the measurement and analysis of THDV ranged from 1.0% - 6.8%, with the final analysis of THDV still meeting the set standard of 5%. THDI ranged from 2.3% - 66.7% with the final analysis THDI did not meet the standard. THD of the village's electrical system is still at the standard limits set and THD(V) effect on PF.

Keywords

Harmonic, THDV, THDI

Full Text:

PDF

References

Grady, W M., & Gilleskie, R J. (2001). Understanding Power System Harmoni. IEEE Power Engineering Review.

Sankaran, C. (2002). Power Quality. CRS PRESS LCC.

Dugan, Roger., & MC, Granaghan. (2002). Electrical Power System Quality 2nd. The MC-Graw Hills Componies.

Grady, W M., & Gilleskie, R J. (2001). Understanding Power System Harmoni. IEEE Power Engineering Review.

Alexander, Marc T Thompson. (2007). Power Quality in Electrical System. The MC-Graw Hills Componies.

Azmi, Riski Lubis. (2017). Efektivitas Penggunaan Pasif Filter LC Dalam Mengurangi Harmonik Arus. Journal of Electrical Technology, 2(3), 2598-1099.

Dultudes, Mangopo. (2007). Pengaruh Distorsi Harmonik Terhadap Faktor Daya. Theses and Dissertations Repository UGM.

Daniel, Rohi., Dion, Utomo., & Ontoseno, Penangsang. (2009). Distorsi Harmonisa Pada Pelanggan Domestik dengan Daya 250 VA Daya 2200 VA. Jurnal EECCIS, 3(1), 2460-8122.

Sunanda, W. (2014). Kandungan Harmonisa pada Lampu Hemat Energi. Jurnal Ecotipe (Electronic, Control, Telecommunication, Information, and Power Engineering), 1(2), 53-56.

Asmar, A., & Sunanda, W. (2021). Studi Kualitas Energi Listrik Gedung Fakultas Teknik Universitas Bangka Belitung. Jurnal Serambi Engineering, 6(2).

Cahyo, S. D., Nisworo, S., & Pravitasari, D. (2021). Audit Kualitas Daya Listrik Rumah Sakit Jiwa Prof. Dr Soerojo Magelang. THETA OMEGA: JOURNAL OF ELECTRICAL ENGINEERING, COMPUTER AND INFORMATION TECHNOLOGY, 2(2), 9-18.

Cahyo, S. D., Nisworo, S., & Pravitasari, D. (2021). Audit Kualitas Daya Listrik Rumah Sakit Jiwa Prof. Dr Soerojo Magelang. THETA OMEGA: JOURNAL OF ELECTRICAL ENGINEERING, COMPUTER AND INFORMATION TECHNOLOGY, 2(2), 9-18.

Arifin, J. (2017). SPSS 24 Untuk Penelitian dan Skripsi. Gramedia.

Institute of Electrical and Electronics Engineers (IEEE). (1992). Recommended Practices and Requirement for Harmonics Control in Electrical Power System. IEEE Standard 519-1992. The Institute of Electrical and Electronics Engineers, Inc.

SPLN D5.004-1:2012. (2012). Power Quality (Regulasi Harmonisa, Flicker, dan Ketidakseimbangan Tegangan. PT. PLN.

Article Metrics

Abstract view: 371 times
Download     : 240   times

Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.

Refbacks

  • There are currently no refbacks.