DAMPAK PEMBERIAN IMPULS ARUS TERHADAP TINGKAT PERLINDUNGAN ARRESTER TEGANGAN RENDAH

Diah Suwarti Widyastuti, Sugiarto Sugiarto

Submitted : 2017-09-14, Published : .

Abstract

Arrester is a device used to protect equipment and electrical systems against overvoltage that one reason is the surge of lightning. Because lightning is a natural phenomenon that the process can not be predicted about time and magnitude of the impulse currents, and if arrester hit by lightning impulse with high peak current value and than arrester is feared can not operate as it should. This research use three impulse current peak value there are 533.33A (0.03 pu), 3866.6A (0.3 pu) and 6858.7A (0.5 pu) tested at low voltage arresters. The test results shown the highest value of leakage current arrester at a maximum voltage of operation (Uc) after buffeted by the current impulse has a value of leakage current 0,32 mA, 0,33 mA and 0,33 mA respectively, still below 1 mA (corresponding international standard IEC 61643-1 Edition 2.0 03/2005). Based on the value of leakage current, it can be said that the arresters in good condition and have not changed the characteristics of volt-ampere (current leaking still relatively the same) and still have good insulating properties even after the current impulse overwritten. The highest value of residual voltage arresters at the peak impulse voltage 10 kV, 15 kV, 20 kV and 24 kV, is 1124 Volt meaning that the margin has exceeded the limit of endurance voltage VW1 class (1000 Volts) amounted to 112.4%, and not exceed the VW2 (2000 Volt) amounted to 43.5%, according to ISO standard 04-7021.21-2004, arresters can be used to protect the electrical equipment with voltage endurance on VW2 class.

Keywords

low voltage arresters, current impulse , the level of protection.

References

__________ , 2004, Peralatan dan Sistem Telekontrol, Standart Nasional Indonesia (SNI)

__________ ,2010, Overvoltage protection, Chapter J, Schneider Electric - Electrical installation guide 2010

Cooray V., 2010, Lightning Protection, Institution of Engineering and Technology, London, United Kingdom

Haryono T., Karya Unggulan Pembangkit Arus Tinggi PLN, 2010, Petunjuk Operasi & Pemeliharaan Lightning Arester, Operation Manual, PLN.

Sirait & Zorro., 1987, Proteksi Terhadap Tegangan Lebih, Jurusan Teknik Elektro FTI ITB.

Tobing L.B., 2003, Peralatan Tegangan Tinggi, PT Gramedia Pustaka Utama.

Zoro R., 2009, Induksi dan Konduksi Gelombang Elektromagnetik akibat sambaran petir pada Jaringan Tegangan Rendah, Makara Teknologi Vol. 13 No. 1, April 2009: 2532.

Article Metrics

Abstract view: 519 times
Download     : 506   times

Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.

Refbacks

  • There are currently no refbacks.